Engineering Calculator
Solve for the orifice bore diameter d that delivers your target ΔP at the given flow. Reader-Harris/Gallagher discharge coefficient, gas expansibility correction, and full validity checks. The same engine flow computers use under the hood.
Actual volumetric flow at upstream P, T — not standard volume.
ID will show below.
Water 20°C = 1.00 cP · Air STP = 0.018 · Light HC = 0.5 · SAE 30 = 100 cP
Range of typical DP transmitters: 10–1000 mbar full-scale.
qᵐ = (C / √(1 - β⁴)) · ε · (π/4) · d² · √(2 · ΔP · ρ)
β = d / D (diameter ratio, valid 0.10 ≤ β ≤ 0.75)
C = Reader-Harris/Gallagher equation per ISO 5167-2 §5.3.2.1
ε = expansibility factor (= 1 for liquid, < 1 for compressible)
Re_D = ρ · v · D / μ ··· must be ≥ 5000 for ISO 5167-2 to apply