Engineering Calculator
Size a control valve for incompressible liquid flow. Get the required Cv (US) and Kv (metric), then check whether your operating ΔP exceeds the choked-flow limit set by the valve's Fᴸ recovery factor. Catches cavitating valves before they show up as trim damage at turnaround.
Specific gravity SG = ρ/1000 (water reference).
Typical sizing ΔP: 25–33% of system loss for good control authority.
Water 20°C = 0.023 bar a · Water 80°C = 0.473 · Hexane 20°C = 0.16
Critical pressure of fluid (water = 220.6 bar a) used for Fᶠ calc; defaults to 220 bar.
Cᵛ = Q · √(SG / ΔP) [Q in US gpm, ΔP in psi]
Kᵛ = Q · √(SG / ΔP) [Q in m³/h, ΔP in bar]
Cᵛ = 1.156 · Kᵛ
Fᶠ = 0.96 - 0.28 · √(Pᵛ/P_c) (liquid critical-pressure ratio factor)
ΔP_choked = Fᴸ² · (P₁ - Fᶠ · Pᵛ)