Engineering Calculator
Compute mean flow velocity in any pipe and verify it stays below the API RP 14E erosional velocity ceiling. Pumped liquids, gas lines, two-phase service — the velocity check that catches under-sized lines before they leak.
ID will show below.
Water = 1000 · Light HC = 850 · Air STP = 1.2 · Compressed gas (50 bar) ~ 50
C-factor per API RP 14E paragraph 2.5. Note: API 14E was withdrawn in 2008 but values remain industry reference.
V = Q / A where A = (π/4) × ID²
V_e (SI) = C_SI / √ρ_kg/m³ (C_SI = 122 for C = 100 imperial)
V_e (Imp) = C / √ρ_lb/ft³ (per API RP 14E, ft/s)