Engineering Calculator
Run the area-replacement check for any welded branch connection per ASME B31.3 §304.3.3. Confirms whether the branch passes unreinforced, and if not, sizes the reinforcing pad. The calc that decides whether you can stub-on or need a fitting.
Header dimensions will show below.
Branch dimensions will show below.
From B31.3 Table A-1 at design temperature. A106-B at 200°C ~ 138 MPa · 350°C ~ 110 MPa.
1.0 seamless · 0.85 ERW · 0.60 furnace-butt-welded.
0.4 ferritic ≤ 482°C · 0.4 austenitic ≤ 566°C · rises to 0.7 above 600°C.
90° = right-angle tee (most common). B31.3 limits oblique branches to ≥ 45°.
Width W = added pad width on each side (total OD = D_b + 2W) · Tr = pad thickness. Set both to 0 for unreinforced check.
t_h = P · D_h / (2 (S · E + P · Y)) (header pressure design thickness, B31.3 §304.1.2)
d₁ = (D_b - 2 (T_b - c)) / sin β
A₁ = t_h · d₁ · (2 - sin β) (required reinforcement)
d₂ = max[ d₁, (T_b - c) + (T_h - c) + d₁ / 2 ] (zone half-width on run)
L₄ = min[ 2.5 (T_h - c), 2.5 (T_b - c) + T_r ] (zone height on branch)
A₂ = (2 d₂ - d₁) · (T_h - t_h - c) (excess in run)
A₃ = 2 L₄ · (T_b - t_b - c) / sin β (excess in branch)
A₄ = 2 W · T_r (added pad)
Compliance: A₂ + A₃ + A₄ ≥ A₁